Log In

Attention all
Automotive Scope Users


Pico Automotive Scope software now sports a new Waveform Library browser.
Must own PicoScope to view.
See details here

 

 

48 Years in Business

 

Follow us on Facebook for all the latest news, updates and promotions

 

Serial Decoding - UPDATE

The new PicoScope beta release, 6.13, adds Modbus RTU and ASCII to its growing list of serial decoders. Modbus is used in industrial automation to communicate with programmable logic controllers (PLCs).

PicoScope 6 now supports a total of 18 serial protocols and is the only oscilloscope that can decode Modbus.

~~~~~~~~~~~~~~~~~

You can use PicoScope to decode data from a serial bus such as CAN bus. Unlike a conventional bus analyzer, PicoScope lets you see the high-resolution electrical waveform at the same time as the data. RS232/UART and SPI formats added to serial decoding mode
 

Credit Cards Accepted

 

Aurora Probability
Northern US States and 
Southern Canadian States.
 

For more precise predictions
go to

https://www.swpc.noaa.gov

Auroral forecast from AuroraWatch.ca

USB Scope Specifications

Converts PC to Oscilloscope (1435 bytes)

PicoScope 2203, 2204,2205,2206,2207 and 2208

[ALL THE ABOVE MODELS REPLACED BY THE "A" Versions]
Link to New 2200A Series


US Prices
CDN Prices

Privacy and Security Policy

 


Waveform buffer  Normal Triggering
Rapid Block Triggering

 

 

Oscilloscope
Variant
PicoScope 2203
(PP418)
PicoScope 2204
(PP419)
PicoScope 2205
(PP420)
PicoScope 2206
(PP800)
PicoScope 2207
(PP801)
PicoScope 2208
(PP802)
Bandwidth 5 MHz 10 MHz 25 MHz 50 MHz 100 MHz 200 MHz
Rise Time (Calculated)   35 ns 14 ns 7 ns 3.5 ns 1.75 ns
Channels 2
Vertical resolution 8 bits
Enhanced vertical resolution 12 bits
Dynamic range 48 dB
DC Accuracy ±3% of full scale
Input ranges (full scale) ±50 mV to ±20 V in 9 ranges
Analog offset range
(Vertical position adjustment)
none ±200 mv (50 mv to 200 mv ranges)
±2.5 V (500 mv, 1 V, 2 V ranges)
±20 V (5V, 10 V, 20 V ranges)
Input characteristics 1 MΩ in parallel with 20 pF or less 1 MΩ ±1% // 13 pf ±1 pf
Overload protection ±100 V (DC AC peak)
Input type Single-ended, BNC connector
Input coupling Software selectable AC/DC
Maximum sampling rate (single shot)
One channel in use
Two channels in use

40 MS/s
20 MS/s

100 MS/s
50 MS/s

200 MS/s
100 MS/s
500 MS/s
250 MS/s
1 GS/s
500 MS/s
1 GS/s
500 MS/s
Maximum sampling rate (repetitive signals) 1 GS/s 2 GS/s 4 GS/s 5 GSs 10 GS/s 10 GS/s
Maximum sampling rate
(continuous streaming mode)
1 MS/s (typical) in PicoScope
Rate using the supplied SDK is PC dependent
Record length
One channel in use
Two channels in use

8 kS/channel
4 kS/channel

8 kS/channel
4 kS/channel

16 kS/channel
8 kS/channel

24 kS/channel
12 kS/channel

32 kS/channel
16 kS/channel

40 kS/channel
20 kS/channel
Record length (in streaming mode) 2 M samples per channel
 

Up to 10,000 waveforms
not applicable

Up to 10,000 waveforms
Up to 32 waveforms
Timebase ranges 50 ns/div to 20 s/div in 27 ranges 10 ns to 1000 s/div 5 ns to
1000 s/div
2 ns to
1000 s/div
1 ns to
1000 s/div
500 ps to
1000 s/div
Timebase accuracy ±100 ppm ±50 ppm

 

Triggers
Source Ch A or Ch B
Basic triggers Rising edge, falling edge, threshold
Advanced triggers none none Pulse width, dropout, window, logic
Spectrum Analyser
Bandwidth 5 MHz 10 MHz 25 MHz      
Frequency range DC to
5 MHz
DC to
10 MHz
DC to
25 MHz
DC to
50 MHz
DC to
100 MHz
DC to
200 MHz
Display modes Magnitude, peak hold, average
Windows types Blackman, gaussian, triangular, hamming, hann, blackman-harris, flat-top, rectangular
Number of FFT Points Selectable from 128 to half the available buffer memory in powers of 2
Arbitrary Waveform Generator
Connector type BNC
Buffer size 4 kS 8 kS
Vertical resolution 8 bits 12 bits
Output range ±125 mV to ±2 V pk-pk with ±1 V offset
Output resistance 600 Ω
Clock frequency 2 MHz
Bandwidth DC to 1 MHz
PC Requirements
Minimum Processor: Pentium II processor, or equivalent
Memory: 64 MB (XP) / 512 MB (Vista) minimum
Operating system:
Microsoft Windows XP SP2, Vista and Windows 7 (32 or 64 bit)
Ports: USB 1.1 compliant port
Recommended Processor: 2 GHz Pentium IV processor, or equivalent
Memory: 256 MB (XP) / 1 GB (Vista)
Operating system: Microsoft Windows XP SP2, Vista and Windows 7 (32 or 64 bit)
Ports: USB 2.0 compliant port
Environmental
Operating temperature range 5 °C to 45 °C
Storage environment
Temperature range
Humidity

-20 °C to 60 °C
5% to 95% RH, non-condensing
Physical Dimensions
Dimensions 100 x 135 x 45 mm (approx 3.9 x 5.3 x 1.8 in)
(Does not include BNC connectors)
Weight 210 g (approx 7.4 oz)
General
Supplied software/hardware PicoScope 6 and PicoLog software
Drivers and examples for LabVIEW, C, C , Delphi and
VB
USB 2.0 cable
PC interface USB 2.0 (USB 1.1 compatible) - cable supplied
Power requirements From USB port
Approvals FCC, CE
  2203
(PP418)
Replaced by PP906
2204
(PP419)
Replaced by PP906
2205
(PP420)
Replaced by PP907
2206
(PP800)
Replaced by PP908
2207
(PP801)
Replaced by PP909
2208
(PP802)
Replaced by PP910
 
 
 
USA Office

Tel:1.877.902.2979-1.425.223.4311
Fax:1.877.329.4324
Address: 1480 Gulf Road, Suite 837,
PO Box 1364
Point Roberts, WA 98281

Western Canada - Vancouver BC

Tel:1.800.663.6001 or 1.604.925.6150
Fax:1.604.925.6170
Address: 2454 Haywood Ave
West Vancouver, BC V7V 1Y1

Eastern Canada - Markham, Ontario

Tel:1.800.465.0164 or 1.905.513.7027
Fax:1.877.329.4324